FHA Appraiser Mandates Utility Requirement by Lore DeAstra, MBA, SRA, CDEI, Author of the FHA Checklist and eBook In an effort to protect ourselves, allow me to relay a recent conversation between an appraiser and agent/builder, that came to me in the form of a question from a reader. The answer is also below. The question said: “An appraiser friend commented that he completed an FHA appraisal the other day and that the real estate agent/builder was surprised when my friend asked the agent/builder to show that the property had working utilities. The agent/builder told him that he had done about five transactions before, with another appraiser, and that the previous appraiser had never asked him to prove that the utilities were operational. The water and electric were on, he said, but not the gas. The agent/builder said that they do not turn the gas on in the summer but that he would make an exception for the appraiser. The fact that the pervious appraiser had not asked for this information seemed odd to my friend, since it was his understanding that confirming working utilities (water, gas and electric) is a requirement by the FHA.” Q: Was the agent/builder and previous appraiser correct in inspecting a home for FHA without utilities? A: Unless the equipment would be damaged if operated, ALL utilities must be on during an appraisal inspection. For instance, if the home had gas heat and the summer temperatures were above 90 degrees, it may damage the air conditioning unit. Solution: The appraiser would then mention the circumstances and offer to re-inspect, when appropriate, later. Q: What if the utilities (water, sewer, electric, gas) are not on? A: Make another appointment when the utilities are operational.
Not convinced? Let us review a direct
quote from FHA, highlighted in
yellow and pink for
your convenience. “Chapter 1, Appraisal & Property Requirements, Page 1-19
Utilities Not On
- Please see:
Mortgagee
Letter 2005-48, Revised Appendix D. For the URAR
-pages D-23 and D-24; for Manufactured Homes - D-55 and D-56; Condos
- D-90; 2-4 Family - D-116 and D-117. When utilities (water, gas,
electric) are NOT on at the time of appraisal the appraiser is to
condition for further inspection to determine if the utilities are
in proper working order. Checking Mechanical Systems - Please see: Mortgagee Letter 2005-48 An appraiser must examine mechanical, plumbing and electrical systems to ensure they are in proper working order. The appraiser should turn on the systems and observe their performance. The appraiser may call for a certification of a system when he/she cannot determine if it is working properly. An appraiser should not arbitrarily call for such certifications and should understand that they are still responsible for checking on the adequacy of these systems at the time of appraisal. For 2-4 units, note the type of heating and cooling for each unit, if different. *Do not operate the systems if doing so may damage equipment, or when outside temperatures will not allow the system to operate. Note in the appraisal report why the system(s) could not be tested. [1]
December 19, 2005 MORTGAGEE LETTER 2005- ML-48
TO: ALL
APPROVED MORTGAGEES SUBJECT: FHA Repair and Inspection Requirements for existing properties and revisions to FHA Appraisal Protocol In September 2005, the Federal Housing Administration (FHA) issued Mortgagee Letter 2005-34, which announced the adoption of four of Fannie Mae’s revised appraisal reporting forms as well as the release of Revised Appendix D of Handbook 4150.2, CHG-1. This Mortgagee Letter provides additional guidance regarding FHA’s repair and inspection requirements for existing properties and the use of the Fannie Mae appraisal reporting forms. All appraisal guidance for new construction that serves as security for FHA-insured mortgages remains unchanged beyond the clarification in the Revised Appendix D that the appraiser may appraise a home that is under construction and that is 90% or more complete without benefit of plans and specifications. In a continuing effort to reform and standardize its appraisal requirements, FHA has shifted from its historical emphasis on the repair of minor property deficiencies and now only requires repairs for those property conditions that rise above the level of cosmetic defects, minor defects or normal wear and tear. FHA Roster Appraisers are reminded to report all readily observable property deficiencies, as well as any adverse conditions discovered performing the research involved in completing the appraisal, within the appraisal reporting form. Lenders should use professional judgment and rely upon prudent underwriting practices in determining when a property condition poses a threat to the safety of an occupant and/or jeopardizes the soundness and structural integrity of the property, such that additional inspections and/or repairs are necessary. Revisions to the appraisal reporting guidance contained in Chapters 2 and 3 of Handbook 4150.2, CHG-1 are limited to those described in this Mortgagee Letter and Mortgagee Letter 2005-34 and Revised Appendix D. The specific areas of guidance that are rescinded by this Mortgagee Letter are delineated below. FHA intends to retire and replace Handbook 4150.2, CHG-1 in the near future.
Repair Requirements
·
Missing handrails
Examples of property conditions that may represent a risk to the health and safety of the occupants or the soundness of the property for which FHA will continue to require automatic repair for existing properties include, but are not limited to:
·
Inadequate
access/egress from bedrooms to exterior of home Lenders must review the appraisal to determine whether the appraiser has reported any property conditions that will affect the health and safety of the occupants or the security and the soundness of the property and must require immediate repair where the property condition poses a threat to these criteria.
Inspection
Requirements
-Corrosion of pipes
(plumbing)
·
Septic: test or inspection
required only if evidence of system failure, if mandated by
state or Consequently, the guidance provided in Handbook 4150.2, Chapter 3, Paragraph 3-6, A-6 referencing mandatory termite inspections for any structure that is ground level and for any structure where wood touches the ground; Paragraph 3-6, A-5 referencing mandatory well and septic tests; and Paragraph 3-6, A-12 referencing mandatory inspections for a flat roof is no longer applicable. Additionally, the guidance provided in Handbook 4905.1, REV-1, Chapter 2, Paragraph 2-5, B-1 referencing mandatory well water tests is no longer applicable. In cases where well tests are necessary, as described above, FHA’s existing testing standards outlined in Chapter 3, Paragraph 3-6, A-5a. of Handbook 4150.2 remain in effect and supercede Mortgagee Letter 95-34. If the appraiser reports a potential property deficiency that may pose a threat to the safety of the occupants or the security and soundness of the property, the lender will require an inspection of the condition to determine whether repairs are necessary to mitigate or resolve the problem. Examples of conditions that will continue to require automatic inspections include, but are not limited to:
·
Standing water
against the foundation and/or excessively damp basements
Conditional
Commitment Form This Mortgagee Letter is effective for all appraisals performed on or after January 1, 2006. If you have any questions regarding this Mortgagee Letter, please contact your local Homeownership Center (HOC) in Atlanta (888) 696-4687, Denver (800) 543-9378, Philadelphia (800) 440-8647, or Santa Ana (888) 827-5605. Sincerely,
Brian D.
Montgomery
FHA
Guide--eBook and Checklist
During these uncertain times, smart real estate
The fastest, most cost-effective, pain-free way to do Features: · Ease of Use · Concise Information in an Easy to Follow eBook, Searchable by Topic · Web Links to Topics for Easy Access
·
Over 10 New
Ways to Access Information and
·
Symbols and
Pictures Included by Topic for At-a- · FAQ from Appraisers and Lenders by Topic with Detailed Index by Page
- FHA Updates: 1. What should you take pictures of if you suspect Hydrogen Sulfide Gas? 2. What's important regarding Conditional Commitments? 3. Economic Life vs. Effective Age? 4. Fannie Mae Form 2055
To purchase, go here
HTML Comment Box is loading comments...
|
||
ATTENTION: You are receiving WRE Online News because you opted in at WorkingRE.com or purchased E&O insurance from OREP. WRE Online News Edition provides news-oriented content twice a month. The content for WRE Special Offer Editions is provided by paid sponsors. If you no longer wish to receive these emails from Working RE, please use the link found at the bottom of this newsletter to be removed from our mailing list. |